Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orthop Traumatol Surg Res ; 104(3): 317-323, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29474948

RESUMO

INTRODUCTION: The PFMR® proximal femoral modular reconstruction implant (Protek, Sulzer Orthopedics, Switzerland) is a straight modular stem in sanded titanium with press-fit anchorage, intended to achieve spontaneous bone reconstruction following Wagner's principle. The aim of the present study was to analyze long-term clinical and radiological outcome. MATERIAL AND METHOD: A single-center retrospective study included 48 PFMR stems implanted in 47 patients between 1998 and 2002. Results in this series were previously reported at 7 years' follow-up. Clinical assessment used PMA and Harris scores. Radiologic assessment focused on stem stability and osseointegration, and bone stock following Le Béguec. RESULTS: Twenty-three patients were seen at a mean 14.5 years' follow-up (13 deceased, 11 lost to follow-up), including 1 with bilateral implants, i.e., 24 stems. PMA and Harris scores, stem stability and osseointegration and bone stock were stable with respect to the 7-year findings. Radiology found 7 stem fractures in the Morse taper, i.e., in 29% of implants. Two of these cases required femoral implant replacement; 5 were asymptomatic. DISCUSSION AND CONCLUSION: Long-term outcome for PFMR stems was clinically and radiologically satisfactory for the 16 patients free of mechanical complications. The Morse taper fracture rate was high, and higher than reported elsewhere. The usual risk factors for implant fracture were not found in the present series. The modular design of the press-fit revision implant is its weak point; monoblock implants should be used in patients with good life-expectancy. LEVEL OF EVIDENCE: IV (retrospective study).


Assuntos
Artroplastia de Quadril/instrumentação , Fêmur/diagnóstico por imagem , Prótese de Quadril , Osseointegração , Desenho de Prótese , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Reoperação , Estudos Retrospectivos
2.
Orthop Traumatol Surg Res ; 102(5): 651-6, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27185332

RESUMO

BACKGROUND: Ankle arthrodesis is a treatment of choice for advanced tibio-talar disease unresponsive to conservative treatment. Using arthroscopy to perform this procedure minimises soft-tissue trauma while providing similar outcomes to those of open surgery. Union rates have ranged across studies from 85% to 100%. The objective of this study was to assess the potential influence on union of the number of screws used for arthrodesis fixation. HYPOTHESIS: The working hypothesis was that using three screws for arthrodesis produced a higher union rate than did using only two screws. MATERIAL AND METHODS: This single-centre retrospective comparative study included 111 cases of arthroscopic ankle arthrodesis (in 108 patients) carried out between February 1994 and October 2012. The number of screws was two in 75 cases and three in 36 cases. Union was assessed on radiographs taken 2, 6, and 12months postoperatively. RESULTS: Mean age at surgery was 55.8years. After 12months, union was achieved in 87.4% cases overall. The non-union rate was 16% with two screws and 5.6% with three screws. Three-screw fixation was associated with a significantly higher rate of union of the medial gutter after 6months and of the lateral gutter after 12months. DISCUSSION: Our findings support the use of three screws for fixation of arthroscopic tibio-talar arthrodesis. Adding a third screw seems associated with a lower risk of non-union and a shorter time to union. These effects can be ascribed to greater stability of the construct. LEVEL OF EVIDENCE: Level IV, retrospective study.


Assuntos
Articulação do Tornozelo/cirurgia , Artrodese/instrumentação , Parafusos Ósseos , Osseointegração , Articulação do Tornozelo/diagnóstico por imagem , Artrodese/métodos , Artroscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Estudos Retrospectivos
3.
Orthop Traumatol Surg Res ; 102(4): 517-9, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27052938

RESUMO

Hip prosthesis implantation requires a stable pelvic foundation, which may be lacking in patients with complex pelvic abnormalities (e.g., arthrodesis conversion, tumour excision, or revision with large bony defects). Many reconstructive options exist for these situations, but their outcomes vary with the initial amount of bone loss and with the technique used. We describe a two-stage arthroplasty technique (acetabular cup first, then femoral stem) and report its use in a case of arthrodesis conversion with concomitant treatment of pelvic and acetabular non-union. Clinical and radiological outcomes after 5 years are reported. This procedure can be adapted to the most complex cases of pelvic reconstruction.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Ossos Pélvicos/cirurgia , Acetábulo/diagnóstico por imagem , Adolescente , Artrodese , Doenças Ósseas Metabólicas/cirurgia , Feminino , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Humanos , Ossos Pélvicos/diagnóstico por imagem , Procedimentos de Cirurgia Plástica/métodos , Reoperação
4.
Orthop Traumatol Surg Res ; 100(6 Suppl): S333-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25155203

RESUMO

BACKGROUND: The objective of this randomised trial was to compare surgical rotator cuff repair to simple decompression by acromioplasty and biceps tenotomy in patients older than 60 years of age with a mean follow-up of 4 years. HYPOTHESIS: Tendon repair produces better functional outcomes than simple decompression and prevents progression towards cuff tear arthropathy in the longer term. PATIENTS AND METHOD: Of 130 initially included patients older than 60 years of age and having rotator cuff tears deemed amenable to surgical repair, 103 (79%) were evaluated after a mean of 4 years. These patients had been randomly allocated to acromioplasty and tenotomy (AT group, n=49) or to acromioplasty, tenotomy, and tendon suture (CR group, n=54). The tear was distal in 41 patients, intermediate in 40, and retracted in 22. At last follow-up, the evaluation included the clinical Constant's Score, radiographs and, in the CR group, ultrasonography. RESULTS: The complication rate was 4%. The mean Constant Score was 44 preoperatively; values after 4 years were 76 overall (P=0.01), 78 in the CR group, and 73 in the AT group (P=0.01). The tendon-healing rate as assessed using ultrasonography was 63%. The Constant Score was significantly better when tendon healing was achieved (82/73, P<0.001). In the AT group, the acromio-humeral distance was significantly shorter (6.9 mm/7.8mm, P=0.03) and eccentric humeral head position was more common (44%/26%, P=0.01). DISCUSSION: Arthroscopic rotator cuff repair provides better functional outcomes than does simple decompression in patients older than 60 years and prevents cuff tear arthropathy with eccentric humeral head position in the medium term. Tendon healing is the main determinant of outcomes after rotator cuff repair. LEVEL OF EVIDENCE: II, randomised trial.


Assuntos
Artroplastia/métodos , Artroscopia/métodos , Lesões do Manguito Rotador , Manguito Rotador/cirurgia , Tenotomia/métodos , Articulação Acromioclavicular/cirurgia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Manguito Rotador/diagnóstico por imagem , Tendões/diagnóstico por imagem , Tendões/cirurgia , Resultado do Tratamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...